Can a PWM rectifier follow requested active power and displacement angle while a three-level NPC stage maintains DC-link regulation and controlled grid export?
Why the validation plan matters
Can a PWM rectifier follow requested active power and displacement angle while a three-level NPC stage maintains DC-link regulation and controlled grid export? Demonstrating this requires defined metrics rather than a single steady-state screenshot. Use the same input profiles and measurement definitions for all compared cases.
Primary measurements
The first traces to capture are requested versus measured rectifier real and reactive power; power factor angle and phase-current waveforms; and dc-link and neutral-point capacitor voltages. Each plot should include a legend, units, axis labels and an explicit measurement window.
Secondary diagnostic measurements
To explain the mechanism behind the result, capture grid inverter active/reactive power and harmonics; rectifier versus exported grid power balance; and current thd with stated analysis window and method. A credible report distinguishes the cause of improved behaviour from a coincidental change in another variable.
Four scenario comparisons
Real-power reference step at fixed phase angle; Displacement-angle step at fixed real power; NPC output load or grid impedance variation; Neutral-point balance and DC-link disturbance. Keep all other parameters unchanged when studying a single variable. Where that is not possible, explain why and include paired comparisons.
Numerical and experimental cross-checks
Power accounting: P_ac,rectifier - P_ac,grid-return - P_loss ≈ dE_dc/dt; the sign convention must be declared before comparing plots. Repeat the numerical test at a finer time step or mesh and record the deviation in the target metric. If published or measured data exist, compare trends and uncertainty bands instead of asserting exact agreement.
Reading the results without overclaiming
The following potential limitations affect interpretation: A modeled three-level inverter requires actual switching states and balancing dynamics, not only a three-level ideal waveform source. Any claimed low THD must come from measured current at a clearly defined port and window. Tracking error depends on sensor definition; controller dq diagnostics are not substitutes for direct V×I power checks. Report results as simulations unless independent experiments substantiate performance.
Technical checklist for this study
- Requested versus measured rectifier real and reactive power
- Power factor angle and phase-current waveforms
- DC-link and neutral-point capacitor voltages
- Grid inverter active/reactive power and harmonics
Related research reading
Continue to the complete project methodology and dedicated video demonstration for an aligned description of the system.